A fully browser-based Modbus RTU master/client tool that communicates with Modbus slave devices over a serial port using the Web Serial API. No installation, no dependencies, no server — just open the HTML file in Chrome or Edge and start querying.


Features

Serial Communication

Supported Function Codes

Code Function Type
FC01 Read Coils Read
FC02 Read Discrete Inputs Read
FC03 Read Holding Registers Read
FC04 Read Input Registers Read
FC05 Write Single Coil Write
FC06 Write Single Register Write
FC15 Write Multiple Coils Write
FC16 Write Multiple Registers Write

Per-Register Data Type Interpretation

When reading registers (FC03/FC04), each register in the response can be individually assigned a data type for interpretation. The following types are supported:

Type Size Registers Used
8-bit INT 8-bit signed 1
16-bit INT 16-bit signed 1
32-bit INT 32-bit signed 2
8-bit UINT 8-bit unsigned 1
16-bit UINT 16-bit unsigned 1
32-bit UINT 32-bit unsigned 2
64-bit UINT 64-bit unsigned 4
32-bit Float IEEE 754 single 2
64-bit Float IEEE 754 double 4
String4 4-char ASCII 2
String6 6-char ASCII 3
String8 8-char ASCII 4
String12 12-char ASCII 6
String16 16-char ASCII 8

Multi-register types (32-bit, 64-bit, strings) automatically span the correct number of consecutive registers. A “Copy #1 → All” button lets you set the first register’s type and apply it to every register in one click.

Byte order options for multi-byte types:

Minus Offset

Many Modbus device manuals use documentation addresses like 40001 for the first holding register, but the actual Modbus protocol uses 0-based addressing. The Minus Offset feature bridges this gap:

A live preview shows the calculated wire address before you send, and the communication log displays both addresses when offset is active.

Auto-Polling

Enable automatic repeated querying at a configurable interval (100ms–60,000ms). Useful for monitoring live values. Toggle on/off with a checkbox — the tool will re-send the current query at each interval.

Device Profiles

Create named profiles to label registers, coils, and inputs for specific Modbus slave devices. Profiles make the response data table much more readable by showing human-friendly names alongside raw addresses.

Each profile stores:

Each profile entry defines:

Automatic FC tab configuration: When a profile is active and you click a function code tab, the tool automatically:

This means you can simply load a profile, click a FC tab, and immediately send a query — no manual address configuration needed.

Profile management features:

When a profile is active, a pink badge appears in the header showing the profile name, and a Label column is added to the response data table. Profile data types are automatically applied to the per-register type selectors. If the profile has no entries for a particular FC tab, an info message is shown with a link to edit the profile — the manual address fields remain available for direct queries.

Switching FC tabs or changing profiles clears the Response Data area, so it’s always clear that a fresh query is needed to populate results for the current context.

Raw Response Frame

Every response is displayed in three formats:

Error Handling

When an error occurs, the response data table is replaced with a clear error message to prevent confusion with stale data.

Collapsible Sections

The following sections can be collapsed/expanded by clicking their headers to reduce clutter:

Communication Log

Timestamped log of all TX (sent), RX (received), and error events with full hex frame data and timing information. Includes a clear button and collapse toggle.


Requirements

Note: The Web Serial API is not supported in Firefox or Safari.


Getting Started

  1. Open modbus-master.html in Chrome or Edge
  2. Configure serial port settings (baud rate, data bits, stop bits, parity) in the sidebar
  3. Click “Connect” — the browser will prompt you to select a serial port
  4. Set the slave ID, start address, and quantity
  5. Select a function code tab (FC01–FC16)
  6. Click “Send Query” to execute the Modbus request
  7. View the response in the data table, with optional data type interpretation

Using Minus Offset

  1. Check “Enable Minus Offset” in the sidebar
  2. Enter the offset value (e.g. 40001 for holding registers, 10001 for discrete inputs, 30001 for input registers)
  3. Enter your documentation address as the Start Address
  4. The wire preview below will show the calculated protocol address
  5. Send queries as normal — the tool handles the address translation

Using Data Types

  1. Send a register read query (FC03 or FC04)
  2. The “Data Type per Register” section appears with a dropdown for each register
  3. Select the desired type for each register (or set the first and click “Copy #1 → All”)
  4. Choose the byte order if working with multi-byte types
  5. The table updates automatically to show the interpreted values

Using Device Profiles

  1. Click the “Profiles” button in the header
  2. Enter a profile name (e.g. “Schneider PM5110”) and the device’s Slave ID
  3. Click ”+ Add Entry” to define each register/coil label:
    • Select the type (Coil, Discrete, Holding, Input)
    • Enter the address number (use documentation addresses, e.g. 40001 for holding register 0)
    • Type a descriptive label
    • Optionally choose a data type (for registers)
  4. Click “Save Profile” to store it locally and activate it
  5. Now simply click any FC tab — the start address, quantity, and minus offset are auto-configured from the profile
  6. Click “Send Query” — the Label column shows your defined names in results
  7. To share profiles, use “Export JSON” and “Import JSON”

Using Auto-Polling

  1. Ensure you are connected to a serial port
  2. Set the desired polling interval in milliseconds
  3. Check “Enable Auto-Polling” to start
  4. Uncheck to stop polling

Write Operations

  1. Select a write function code (FC05, FC06, FC15, or FC16) — the button changes to “Send Update”
  2. With a profile active: A picker list shows all labelled registers/coils for the selected type. Click to select which ones to write, enter values inline, then click Send Update. For non-contiguous selections (e.g. registers 1 and 3 but not 2), the tool sends individual write commands to avoid overwriting unselected registers.
  3. Without a profile (or no entries for that type): The manual value input appears with guidance for the expected format:
    • FC05 (Single Coil): 1, 0, true, false, on, off
    • FC06 (Single Register): An integer between 0 and 65535
    • FC15 (Multiple Coils): Comma or space-separated 1/0 values
    • FC16 (Multiple Registers): Comma or space-separated integers (0–65535)
  4. Click “Send Update” to execute the write

Auto-polling is automatically stopped when switching to a write FC tab to prevent accidental repeated writes.


File Structure

modbus-master.html    — Main application (single self-contained HTML file)
download-fonts.sh     — Script to fetch font files locally
README.md             — This file
fonts/                — Local font files (created by download-fonts.sh)
  JetBrainsMono-*.woff2
  Outfit-*.woff2

No external dependencies, build steps, or server required. All HTML, CSS, and JavaScript are inline. Fonts are loaded locally with no external network requests.


Browser Compatibility

Browser Supported
Google Chrome 89+
Microsoft Edge 89+
Opera 76+
Firefox ❌ (no Web Serial API)
Safari ❌ (no Web Serial API)